I-Desktop ye-High-speed Refrigerated Centrifuge

Inkcazelo emfutshane:

TGL series desktop high-speed centrifuge refrigerated isetyenziselwa iintsholongwane, protein, nucleic acid extraction, subcellular component separation, clinical test sample processing, ilungele unyango, isayensi yobomi, biopharmaceutical, isayensi yezolimo, ukhuseleko lokusingqongileyo kunye nezinye iiyunithi zophando lwenzululwazi, iiyunivesithi.


Iinkcukacha zeMveliso

Iithegi zeMveliso

Iimbalasane

m1627625017

Iteknoloji eluncedo
I-steel-multi-layer-proof-proof-proof structure, insimbi engenasici kwi-centrifugal cavity.
Ulondolozo-free DC variable frequency motor drive, ukusebenza egudileyo kwaye cwaka.

Ulawulo oluchanekileyo lweprosesa ye-Microcomputer, umboniso wedijithali, umsebenzi olula, ukubala okuzenzekelayo kwexabiso le-centrifugal amandla e-RCF, isantya kunye namandla e-centrifugal anokutshintshwa kunye nesinye isitshixo esinye.

Yamkela iyunithi yecompressor engena-fluorine, ifriji ephindwe kabini, ubushushu obunamandla kunye nomthamo wokutshintshiselana ngokubanda, ulawulo oluchanekileyo lobushushu, ukupholisa ngokukhawuleza kwaye akukho ngcoliseko lokusingqongileyo.
Ukukhawuleza kwe-10 kunye nokulawulwa kokunciphisa, Gcina amaqela angama-10 eenkqubo ezisetyenziswa ngokuqhelekileyo.

Thulisa isitshixo socango oluzenzekelayo lwe-elektroniki, kulula ukuyisebenzisa, kunye nomsebenzi wokuvula umnyango kaxakeka.
Umkhono we-cone wasentwasahlobo usetyenziselwa ukudibanisa i-rotor kunye ne-shaft engundoqo.I-rotor ilula kwaye ikhawuleza ukuyifaka kunye nokususa, i-non-directional, ikhuselekile kwaye inokwethenjelwa.

Isitshixo socango, isantya esiphezulu, ubushushu kunye nokungalingani ukhuseleko oluzenzekelayo,Impazamo yokuzixilonga.
Kupasiswe ISO 9001, ISO 13485, CE, TUV isatifikethi.

Isantya esiphezulu 16000r/min Ubukhulu be-RCF 20600*g
Umthamo omkhulu 6*100ml Uluhlu lobushushu -20℃~40℃
Isibali-xesha 1 ~9h/59min Ingxolo ≤60dBA
Ubungakanani 610*570*370mm Ukusinda okushiyekile 82KG
Ukuchaneka kwesantya ±20r/min Ukunikezwa Amandla AC220/100V,50/60HZ,10A
Ukuchaneka kobushushu ±1℃

I-TGL16 ehambelanayo neeRotors

Rotors No. Uhlobo lwe-Rotors Isantya esiphezulu(r/min) Umthamo(ml) Ubukhulu be-RCF(×g)
No30401 I-Angle rotor 16000r/min 12×1.5/2ml 17940×g
No30402 I-Angle rotor 14000r/min 40 × 0.5ml 19970×g
No30403 I-Angle rotor 15000r/min 24×1.5/2ml 20600×g
No30404 I-Angle rotor 13500r/min 30×1.5/2ml 19340×g
No30405 I-Angle rotor 15000r/min 16×5ml 19350×g
No30406 I-Angle rotor 14000r/min 12 × 7ml 16370×g
No30407 I-Angle rotor 10000r/min 12 × 15ml 11840×g
No30408 I-Angle rotor 12000r/min 12 × 10ml 14510×g
No30409 I-Angle rotor 12000r/min 8×20ml 14510×g
No30410 I-Angle rotor 12000r/min 6×30ml 14000×g
No30411 I-Angle rotor 11000r/min 6×50ml 13480×g
No30412 I-Angle rotor 10000r/min 6×70ml 10810×g
No30413 I-Angle rotor 10000r/min 4×100ml 10310×g
No30414 I-Angle rotor 10000r/min 6×100ml 11380×g
No30415 I-Angle rotor 14000r/min 6×10ml 16460×g
No30416 I-Angle rotor 15000r/min 30 × 0.5ml 18510×g
No30639 I-Angle rotor 5000r/min 24×15ml 3080×g
No30627 I-Angle rotor 5000r/min 30×15ml 3830×g
No30437 Swing rotor 12000r/min 24 iipcs Capillary 15800×g
No30444 I-Angle rotor 11000r/min 48×1.5/2ml 12840×g
No30980 Swing rotor 13000r/min 4×5ml 14960×g
No30935 Irotor ethe nkqo 14000r/min 16×5ml 12660×g
No30676 I-microplate rotor 4000r/min 2×3×48 Kulungile 2300×g
No306 I-Angle rotor 14000r/min 4×8PCR(0.2ml) 12070×g
No306 I-Angle rotor 13000r/min 6×8PCR(0.2ml) 16080×g
No306 I-Angle rotor 14000r/min 8×8PCR(0.2ml) 13390×g
No306 I-Angle rotor 13000r/min 12×8PCR(0.2ml) 17220×g

  • Ngaphambili:
  • Okulandelayo: